Spiral stairs must meet the vertical clearance requirements in paragraph d 3 of this section.
Osha door landing requirements.
Landing requirements for egress exterior doors.
This guide explains scoping and technical requirements for accessible entrances doors and gates in the ada standards.
1910 25 b 3 stairs have uniform riser heights and tread depths between landings.
When a door or a gate opens directly on a stairway a platform is provided and the swing of the door or gate does not reduce the platform s effective usable.
Stairways that will not be a permanent part of the structure on which construction work is being performed shall have landings of not less than 30 inches 76 cm in the direction of travel and extend at least 22 inches 56 cm in width at every 12 feet 3 7 m or less of vertical rise.
09 10 2002 1910 36 b minimum width of exit routes.
Application this section covers all stairways including standard spiral ship and alternating tread type stairs except for articulated stairs stairs that change pitch due to change in height at the point of attachment such as those serving floating roof tanks stairs on scaffolds stairs designed into machines or equipment and stairs on self propelled motorized equipment.
After all these wise choices are made double check them against the minimum code requirements.
The door that connects any room to an exit route must swing out in the direction of exit travel if the room is designed to be occupied by more than 50 people or if the room is a high hazard area i e contains contents that are likely to burn with extreme rapidity or explode.
The general requirement for the specified egress door is a maximum 11 2 in.
Step from the threshold down to the landing on both sides of the door.
Door swing shall not reduce effective standing area on the landing to less than 18 inches 45 72 cm in depth.
The revision in the 1988 ubc which limited the door to opening on an interior stair and excluded exterior stairways was an important change that is often overlooked.
Minimum number at least 60 of public entrances must be accessible in new construction in addition to entrances directly serving tenancies parking facilities pedestrian tunnels and elevated walkways.
1910 36 there are no specific osha standards or requirements applicable to overhead doors.