The flex duct makes the bends easy don t kink it and allows the fan to be repaired from below in the future.
Ok to attack duct directly to roof vent.
The high humid air doesn t vent out of the house before it condensates in the duct and then runs back into the house causing damage.
Insulating the duct may also help.
First plan your route.
After sleeping on it i am having a hard time coming up with any legitimate reason it can t work and can t think of any problem it could cause.
I d recommend venting out the gable.
The owner s manual will usually tell you specifics on duct sizes and lengths.
For that length i don t think you need to worry.
Section of straightened coat hanger into a drill.
Today i saw a very creative way to vent bathroom fans.
The official recommendation from the adc is that flex ducts should sag no more than 1 2 per foot of length between supports.
Although this isn t always possible in attic crawl spaces you should always insulate the duct to prevent condensation problems.
Rafter vents or insulation baffles install in any rafter space to create narrow gaps that direct fresh air from the soffit vents to the peak of the roof.
The safest way to check the attic directly above the stove is to chuck an 18 in.
You may have a bad boot around the roof vent that is leaking into the attic.
This article describes routing bath exhaust fan duct upwards through an attic or roof space or downwards through a floor or crawl space.
I have never seen this before and at first thought considered it wrong.
These specialty vents do not affect the.
Or you may have a distance issue.
The vent should exit the building through the roof or wall at least 3 feet away from any other building openings and the vent cover which must not include a screen should allow dispersal of.
Bathroom ventilation fan duct routing routing a bath vent duct down out or up through an attic or roof out.
Another biggie that i see all the time is sagging ducts.
The fan ducts were attached to a t fitting in the 4 inch abs main sewer vent stack in the attic just below the roof.
Run a rigid vent from the gable wall to a point near your install and use a 2 piece of flex duct to connect the fan to the rigid vent.
If you can put an equal size duct inside the turn as shown below they say you re ok.
No you shouldn t use a towel or other absorbing material.
The best exhaust fan venting is through smooth rigid ducts with taped joints and screwed to a special vent hood.
In all cases the ducting needs to conduct the exchaust to the building exterior and needs to terminate in an animal proof vent cover.
Every register should be fed directly from the central unit or basement trunk line by its own duct.
Loosely hold the wire and direct it through the ceiling drywall approximately where your vent pipe will go.