After adjusting the electrodes vacuuming and replacing strainer we put everything back in place and bled for about 2 3 gallon oil the water heater burner fired up without problem.
Oil fired hot water heater troubleshooting.
If electrical switches oil tank level and thermostat have been checked and the furnace will still not operate the reset switch on the oil burner is the final troubleshooting task before calling.
An improperly installed shutoff valve on a water heater can be very dangerous risking an explosion.
Connect the wires from the ignitor to the contacts on your ignition transformer.
This will be the box shaped object that produces the spark on the electrode.
It may be necessary to temper incoming water supply.
2 extremely cold water going into the heater will decrease the amount of hot water produced.
Close the cold water valve this valve lets water enter the heater tank open a hot water faucet located nearby this relieves the water pressure in the tank remove the sacrificial anode.
Check the hot water piping and control valves connected to the water heater for leaks support and for proper location of shutoff valves.
And oil burner noise smoke odors.
If you ve checked all of those causes and found nothing wrong you might try to reset the entire heating system.
The boiler s automatic filling system controlled by the pressure reducing valve should maintain the proper water level at 12 to 15 psi of pressure.
There should be a red button on the outside of your oil furnace.
Combination thermostat gas valve set too low for desired water temperature.
Carefully turn on your circuit breaker.
Not enough hot water.
If there is electricity reaching the system it will attempt to restart.
The reset button is red and needs to be pressed and held for about a count of three and then released.
Cold inlet water temperature is very cold.
Check dial on combination thermostat gas valve.
If it indicates water you ll have to drain the tank and inspect it for cracks.
Install a new sacrificial anode.
Oil burners used on oil fired heating boilers furnaces or water heaters can often be diagnosed using a visual inspection approach as well as optional simple test equipment described here.
Arrange to repair all cracks.
The flame looks normal no sparks no black smoke in flame or out of the chimney.
To avoid problems in the future or at least minimize them make sure you inspect the sacrificial anode of your heater in intervals of three to ten years.
To check for presence of water in the tank apply some water sensitive paste onto a long stick.
This article series answers most questions about all types of heating system troubleshooting inspection diagnosis and repairs.
Press this button and watch the ignitor tip.